OmniCure® LED Light Meter

OmniCure LED Light Meter

With an ergonomically designed sensor and a fine aperture with a precise calibration, the OmniCure® LED Light Meter helps ensure accurate and consistent measurements over a broad dynamic range from an OmniCure® LED UV curing system or any other LED UV source.

An accessory to the LED Light Meter is the OmniCure® Beam Positioning Kit which enables accurate beam alignment to consistently measure peak irradiance. The Beam Positioning Kit can be combined with the OmniCure® LED Light Meter and the LX400+ to provide a complete UV LED curing solution for assembly manufacturing.


Given that an LED UV source is not monochromatic or a broadband source, light measurements of the LED source can present unique challenges. In order to capture the responsivity of the narrow band wavelengths, choosing an appropriate sensor and performing precise calibrations of multi-point wavelengths is critical.

The OmniCure® LED Light Meter can measure power and irradiance by selecting a specific wavelength on the meter that corresponds to the wavelength of the LED UV source. This enables manufacturers to achieve greater accuracy with ease of use while maintaining reliable and controlled UV assembly processes.

  • » Features & Benefits
  • » Specifications
  • » Dimensions
  • » Illustration of Use
  • » Accessory

Feature

Benefit

Small Form Factor Can be easily adapted in a fixture or restricted space
Multi-point Wavelength Calibration Accurate irradiance/power measurements
Wide Linear Dynamic Range (50mW/cm² to 25W/cm² ) Ability to measure from wide variety of LED light sources
Peak Hold Function Detects peak measurement and records the value
NIST, NRC Traceable Traceability for QA process

Description

 
Spectral Sensitivity Selectable wavelengths programmable from 320-750nm
Measurement Range Irradiance: 50mW/cm² to 25W/cm²
Power: 1mW to 500mW
Accuracy +/- 10%
Resolution Irradiance: 1mW/cm²
Power: 1mW
Calibration Cycle One Year
Battery Life Two Years, Typical (intermittent use)
Operating Temperature Range Ambient to 40° Centigrade
Certification complies with IEC, Canadian and US Standards, RoHS compliant
Functions Peak Hold, Power On/Off, λ nm (Wavelength selection), Power/Irradiance
Traceability NIST and NRC Compliant
Sensor Dimension (L x W x H) 163mm x 100mm x 44mm
Meter Dimension (L x W x H) 75mm x 25mm x 11.95mm

Dimensions

OmniCure LED Light Meter - Dimensions

Illustration of Use

OmniCure® LED Light Meter in use with the OmniCure® LX400 Curing System

OmniCure LED Light Meter - Illustration of Use

OmniCure® Beam Positioning Kit

OmniCure LED Light Meter - Dimensions

Feature

Benefit

Precision screw drive XY axis positioner Enables accurate positioning of the beam on the detector aperture for consistent measurements
Graduated block with stop screw Presets focal distance for the lens type in use to measure peak irradiance
Small form factor Easily slides in the curing station for quick measurement

P/N

Description

019-00131R OmniCure® Beam Positioning Kit

UV LED Spot Curing System
Controller
Focusing Lenses for UV LED Heads
UV LED MAX Head
365nm/125mm UV LED Head
365nm/55mm UV LED Head
385nm/125mm UV LED Head
385nm/55mm UV LED Head
400nm/55mm UV LED Head
UV LED Heads
Focusing Lenses for UV LED Heads
UV LED Head Lenses
Extension cables used with UV LED Head
Extension Cable
Clamp with Extension Rod
Mounting Clamps